Siemens DEKA 1
Flow-Matched Sets

57 lb / hr
Injector

Siemens 3102
click on image to zoom
Siemens Part # FI11402 (old P/N 3102) (Commonly known as Siemens 55's)
All tests run with n-Heptane (0.6855g/mL) @ 20oC (+/-1oC), 3.0 Bar (+/-0.01 Bar) (43.5PSI) , 14VDC (+/-0.05VDC), peak/hold driver. Gas (0.735g/mL) ratings converted at a 1.035:1 ratio.

Static Flow Rate: 57.1 lb/hr = 7.2g/s = 587cc/min (+/-4%)
Dynamic Flow Rate 2.5ms PW @ 100Hz: 12.5 mg/pulse (+/-4%)
Coil Resistance: 2.35 Ohms / Low Impedance / Low-Z (Peak/Hold driver circuit required)
Spray Pattern: Pencil
Connector: Minitimer (Bosch EV1)
> Click here for dimensions <
Factory fitted with Viton upper and lower o-rings. 
Grease supplied to lubricate o-rings prior to installation. 
Note: Siemens DEKA 1 low impedance injectors are able to operate at very high pressures with little degradation in performance. Some new production has silver colored bodies vs. black.
Dynamically flowed and grouped to within 1% tolerance using Racetronix custom injector flow bench
Note: Some injector flow rates have been converted from n-Heptane test solvent to 40CFR86.113, the U.S. EPA emission test gasoline. However, n-Heptane is not gasoline and flows in most common injector designs at about a 3 to 4% lower rate than 40CFR86.113, the U.S. EPA emission test gasoline.